中文字幕无码中文字幕有码在线,亚洲大尺度无码无码专区,日韩毛片无码永久免费看,污亚洲午夜网

浩瀚色譜(山東)應(yīng)用技術(shù)開(kāi)發(fā)有限公司
當(dāng)前位置:供應(yīng)信息分類 > 儀器 > 氣體分析儀 > 可燃性氣體檢測(cè)儀

氧er丙jing-chromsorb-G填充柱應(yīng)用安捷倫島

氧er丙jing-chromsorb-G填充柱應(yīng)用安捷倫島
  • 氧er丙jing-chromsorb-G填充柱應(yīng)用安捷倫島
  • 供應(yīng)商:
    浩瀚色譜(山東)應(yīng)用技術(shù)開(kāi)發(fā)有限公司
  • 價(jià)格:
    面議
  • 最小起訂量:
    1個(gè)
  • 地址:
    山東滕州市(商務(wù)部和技術(shù)部)
  • 手機(jī):
    13963221227
  • 聯(lián)系人:
    王經(jīng)理 (請(qǐng)說(shuō)在中科商務(wù)網(wǎng)上看到)
  • 產(chǎn)品編號(hào):
    216619201
  • 更新時(shí)間:
    2025-04-25
  • 發(fā)布者IP:
    27.215.153.214
  • 產(chǎn)品介紹
  • 用戶評(píng)價(jià)(0)

詳細(xì)說(shuō)明

  浩瀚色譜采用大氣預(yù)濃縮儀-GC/FPD建立了環(huán)境空氣中7種含硫化合物的測(cè)定方法。結(jié)果表明,經(jīng)惰性化改造后的大氣預(yù)濃縮儀-GC/FPD測(cè)定系統(tǒng)的基線低,對(duì)硫化物無(wú)殘留。7種化合物的線性回歸方程的相關(guān)系數(shù)均在0.995以上,高、中、低3種濃度的空白加標(biāo)回收率分別為98.6%105.3%、99.1%103.7%、85.7%99.7%,除硫化氫的相對(duì)標(biāo)準(zhǔn)偏差為10.9%外,其余6種含硫化合物的相對(duì)標(biāo)準(zhǔn)偏差可控制在6.9%以內(nèi)。當(dāng)進(jìn)樣體積為400 m L時(shí),方法的檢出限在0.101.1 ng/m3。CO2、H2O對(duì)實(shí)際樣品的測(cè)定無(wú)干擾。因此,該方法能夠滿足目前監(jiān)測(cè)工作的要求,更加適用于環(huán)境空氣中痕量含硫化合物的測(cè)定。

  名稱:填充柱

  型號(hào):25%β,β-氧二丙腈/chromsorbG(60~80目)

  規(guī)格:3m*3mm

  *高使用溫度:120°C

  編號(hào):20240613009

  應(yīng)用:GB-T 14678-1993 空氣質(zhì)量 硫化氫、甲硫醇、甲硫醚和二甲二硫的測(cè)定 氣相色譜法

  適用于安捷倫6890,7890,7820,8860,8890

  Haohan Chromatography established a method for the determination of 7 sulfur-containing compounds in ambient air using an atmospheric pre concentration instrument GC/FPD. The results showed that the baseline of the atmospheric pre concentration instrument GC/FPD determination system after inerting modification was low and there was no residue of sulfides. The correlation coefficients of the linear regression equations for seven compounds are all above 0.995. The blank spiked recovery rates for high, medium, and low concentrations are 98.6% 105.3%, 99.1% 103.7%, and 85.7% 99.7%, respectively. Except for hydrogen sulfide, the relative standard deviation of the other six sulfur-containing compounds can be controlled within 6.9%. When the injection volume is 400 m L, the detection limit of the method is 0.101.1 ng/m3. CO2 and H2O have no interference with the determination of actual samples. Therefore, this method can meet the requirements of current monitoring work and is more suitable for the determination of trace sulfur-containing compounds in ambient air.

  Name: Filled Column

  Model: 25% β, β - Oxypropionitrile/chromsorbG (60-80 mesh)

  Specification: 3m * 3mm

  *High operating temperature: 120 ° C

  Number: 20240613009

  Application: GB-T 14678-1993 Air Quality Determination of Hydrogen Sulfide, Methylthiol, Methyl Sulfide and Dimethyl Disulfide Gas Chromatography

  Applicable to Agilent 68907890782088608890